Toshiba Industrial Systems
Home > Products
> Toshiba > PLCs
Toshiba's S2E/S2T PLC controllers are small, modular type programmable controllers suitable for
simple relay replacement all the way to complex control applications. Toshiba S2E/S2T are 3rd generation T2 Series CPUs used
with V-Series racks, I/O, and standard AC/DC sower supplies. The S2E/S2T provides a functional, economical, and compact
solution to a wide range of applications in automotive, machine control, and process control systems.
Key Features
- T-Series Compatible. Any program written for a T-Series CPU can be downloaded directly into the S2E/S2T without
modification.
- Comment Storage in CPU. Device/register tags and comments can be stored in CPU module. Tags and comments can be
viewed in the on-line mode without access to the original program.
- Large Program Memory.
|
 S2E/ST2 Series |
|
If you are looking for Toshiba PLC, please call us at (800) 894-0412 or email us at
info@ctiautomation.net we will do our best to help you
find the Toshiba Programmable Logic Controllers that you are looking for at the most competitive prices possible. If you are
searching for Toshiba Micro PLCs technical information (data-sheets) please use the datasheets or product selection guide
page links.
|
The T1 micro Programmable Controllers are PLCs with optional expansion I/O. The communications
capability, advanced instruction set, and large memory (program and data register) make them ideally suited for applications
previously requiring larger more expensive programmable controllers. High-speed performance make these controllers especially
suited for sophisticated machine control applications.
Key Features
- High performance software to include; indirect addressing, 'for/next' loops, pre-derivative real PID and over all 76
insertable function instructions.
- Immediate interrupt function for controlling critical outputs.
- Large Memory, 8k program, 4k data registers, 256 timers & 256 counters.
- Pulse/PWM output for stepper motor control. These transistor outputs can also be used for continuous or high speed
swithing.
- RS485 port for networking to high level controller, other PLCs or Toshiba's ASDs.
- ASCII message storage in register memory for use with low cost OIS.
|
 T1 Series |
Toshiba T1-16S is a micro programmable controller with optional add-on expansion I/O modules. Its
communications capability, advanced instruction set, and large memory (program & data register) make it ideally suited for
applications previously requiring larger more expensive programmable controllers. The Toshiba PLC T1-16S's high-speed
performance makes it especially adapt at sophisticated machine control applications. The T1-16S is a micro Toshiba PLC. But it
has a large program and data memory. Sophisticated machine control applications require high-speed data manipulation. The
T1-16S Toshiba Programmable Logic Controller is designed to meet these requirements. |
 T1-16 Series |
The S2E/S2T Toshiba PLC configurations are available from a very simple 3 I/O slot system to a to a large
local system with several networking options. The simplest configuration consists of a power supply, S2E/S2T CPU, and any
combination of 3 I/O or network modules. A fully integrated system consists of a power supply, an S2T Toshiba CPU, a computer
module, and any combination of 6 I/O or network modules. A maximum system consists of a main rack and 3 expansion racks. Each rack
can have up to 8 I/O modules. Expansion racks can also accept network modules. In addition to V-Series expansion racks, T2 Series
expansion racks can also be connected to the main rack. A combination of V-Series and T2 Series expansion racks is possible. |
 V2000 Series |
Profibus is an international fieldbus for plant wide use across all sectors of the manufacturing and
process industries. It is certified by International Standards IEC-61158. Toshiba offers two Profibus modules for the V2000
Series PLCs, the GPF611**S and the GPF612**S. Both of these modules operate on the Profibus DP network. The GPF611**S is a
Profibus DP master module. It allows the V2000 CPUs (S2/S2T/S2E) to read and write data to slave devices such as;
constant frequency inverters, manifold valve controllers, operator interface stations, flow meters, control valves, remote
field I/O, other PLCs, etc.
The GPF611**S module can communicate with any Profibus DP slave. The GPF612**S is a Profibus DP slave module.
Any Profibus master (V2000 with GPF611**S module, other manufacture's PLC, or higher
level Profibus master) can read and write to a V2000 (S2E/S2T/S2E) controller that has a GPF612**S module in its rack. |
 Profibus Modules |
The GCF612 is a multi function serial communications module for the V2000 Series S2T PLC. It
communicates directly with the S2T CPU via the station bus. The GCF612 has three modes of operation:
- Computer Link Mode
- Free ASCII Mode
- Data Storage Mode
All three modes can be used simultaneously. |
 Serial Modules |
|
Gateways are protocol converters that allow any device with a modbus RTU protocol, Diesel CAN J1939
protocol or Profibus master to talk to Toshiba. In some cases Gateway allows the Toshiba PLC to communicate directly with
other devices using the other device's native protocol. Gateway setup software is used to map the registers between the
other devices/controllers to registers in the Toshiba PLC, ASD, or Loop Controllers. Using a simple spreadsheet format,
Gateway can be configured to fetch a specified number registers or bits from one device and transfer them to the other
device.
- Gateway Modbus allows Toshiba PLCs to be Modbus master or slave.
- Gateway CAN allows Toshiba Controllers to read status of Diesel engines, RPM, Operating Temperature, Hours of
Operation, etc.
- Gateway Profibus allows Toshiba PLCs, ASDs, and Loop Controllers to be slaves on a Profibus DP network.
- All Gateways are setup using the same configuration software.
- Power and Transmit LEDs for each port to show operation status.
|
 Gateways Modbus, CAN, Profibus Converters |
|
The Eagle I/O is universal serial analog I/O. For the analog inputs, the Eagle I/O performs the A to D
(analog to digital) conversion and loads a digital value directly into a T1 register. For analog outputs, the Eagle I/O reads a
digital value out of a T1 register and performs a D to A (digital to analog conversion). Analog signal types and PLC registers
are defined using simple setup software.
- Eagle analog serial I/O can be used in addition to Toshiba parallel I/O
- Several different types of thermocouple and RTD inputs are available.
- Can also work as a Modbus remote slave
- Screw or DIN rail mountable.
|
 Eagle I/O Converters |
|
The TCNV485-232C is a RS485 to RS232 converter. It is primarily used to go from a computers RS232 port
to the RS485 port on a PLC. It can also be used to go from the RS232 port on a PLC to the RS485 port on a higher level
controller. The TCNV485-CMOS is a RS485 to CMOS/TTL converter. It is primarily used with ASDs (Adjustable Speed Drives)
that do not have an RS485 port but need to be networked to a higher level controller.
- Power and Transmit LEDs for each port to show operation status.
- Designed for rugged industrial environments.
- Screw or DIN rail mountable.
- TCNV485-CMOS has 40 cm cable with RJ45 connector for connection to ASD.
|
 Signal Converters |
|
EC300 Series Single/Dual Loop Controller
- Toshiba's single/dual-loop controller EC300 series is equipped with auto-tuning feature and multi-loop control
capability.
- Flexible configuration with the combination of function blocks.
- Simple configuration with pre-defined functions.
- Powerful two-degree-of-freedom PID control algorithm with auto tuning.
- LCD back-lit color display for clear recongnition of process data.
- Parameters and programs stored in handy IC memory cards.
- Connection to PC or PLC via MODBUS(1:N) or ECBUS(N:N).
- System integration with major SCADA packages including Intellusion's FIX DMACS.
|
 EC300 Series |
|
LC500 Series Multi-Loop Controller
The LC500 series controller is born out of the V-Series Integrated controller platform and repackages the
functionality of the Model 1000 product into a 'DIN' size controller profile. The product is available as the LC511 (analog
output type) and the LC512 (pulse output type).
The product can support up to 8 PID process loops, 128 Analog input points and 32 discrete I/O. Up to an
additional 7 loop displays units can be connected to the main unit to display individual loop status. These units are
connected via a RS485 Multi-drop network. Additional I/O modules (up to 15) are added via the RS485 Process I/O Bus.
LC500 can realize the display and operation of total 8 loops when connecting maximum 7 loop display units
(LD512H), added to main loop display. The display and operation up to maximum 8 loops is also enabled by loop switching
operation of main loop display unit.
|
 LC500 Series |
The OIS series Toshiba Touch Panels are used as Operator Interface Stations (OIS) for PLCs, Adjustable
Speed Drives, and V Series Integrated Controllers. Operators know immediately the status of the connected equipment and they
can easily get more detailed information, change operating parameters in the connect equipment or control operation.
|
 OIS Series Touch Panels |
The T1-16S is 8 times faster than Toshiba's earlier M20/M40 PLCs. The T1-16S offers 21 basic
ladder instructions and 97 insert able function instructions. Subroutines, Interrupt functions, Indirect addressing, For/Next
loops, Increment/Decrement, Prederivative PID, etc. are standard on the T1-16S. These functions allow the T1-16S to be applied to
the most complex and demanding control applications. There are four types of T1-16S controllers depending on the built-in functions
and the power supply voltage. A maximum 8 I/O modules can be connected to each T1-16S Toshiba Controller. The T1-16S has two
high-speed counter inputs. These 5k pps (pulse per second) counters can be used independently (of each other and of the CPU scan)
for discrete parts count in applications requiring high-speed compare, reset, and strobe. The counters can also be used together
as a quadrature counter to count a 2-phase pulse encoder signal. In the quadrature counter mode, the counting speed is max 20k cps
(counts per second).
The T1-16S Toshiba Prosec PLC also has a pulse output function (5k pps max). It can generate variable frequency
pulse trains CW and CCW. This output can be used to drive a stepper motor. By using these functions together, an inexpensive motion
control system can be implemented with the T1-16S. The T1-16S has an advanced PID (Proportional, Integral, and Derivative) control
function. This PID function and the analog I/O modules enable the T1-16S Toshiba PLC to be applied to many process control
applications. Multiple PID loops can be used, limited only by the max allowable I/O. The T1-16S enhanced version has a built-in
RS485 communication port. By using this communication port, up to 32 T1-16Ss can communicate with a computer or other higher-level
controller. Most major SCADA software supports T-series PLC communication protocol. A DDE server software (T-PSV) is also
available. When using the T-series programming tool (T-PDS) in this configuration, each station can be programmed remotely. A
multi-drop adapter (CU111) allows an enhanced T1-16S to have two RS485 ports or for a standard T1-16S to have remote capability
added after installation. The T1-16S Toshiba Prosec PLCs' enhanced version's RS485 port supports the data link mode. Using the data
link mode, two T1-16Ss can exchange data each other (16 words input and 16 words output). The update cycle for the total 32 words
is approx. 50ms. No user program required for this data linkage.
A typical S2E/S2T Toshiba PLC system consists of a base rack with modules mounted on the rack. From left to
right modules are: Expansion Interface, Power Supply, CPU, and I/O modules. If the rack supports the station bus, then a computer
module or higher level network module can be mounted following the CPU module. It is no surprise that Toshiba Corporation, a
company well known for rugged laptop computers, also has computer modules for its automation product line. The C2 module is a
Pentium III air cooled, fan-less computer designed for harsh industrial and process environments. There are three models available.
All the components typically found on a computer are located on the front of the Toshiba C2 computer module. The hard disk in the
C2 module (PU37) is removable. Hugh amounts of data can be stored and easily removed from the computer at a more convenient time.
It also permits easy replacement of the computer component most likely to experience an operational problem. Company MIS/IT
departments can easily clone a hard disk so that a backup is available for critical applications.
Whether we have Toshiba PLCs in stock in or need to ship direct from Toshiba Industrial Systems to any USA
cities; CTi Automation can get Toshiba Programmable Logic Controllers to you fast and save you some money. Our Toshiba Industrial
Systems distributors warehouse stocks some Toshiba PLC products enabling us to further assist you in finding the correct Toshiba
T1 Micro PLCs in the USA, Canada, or Mexico. It will be very helpful if you have the Toshiba PLC part numbers ready, then our
sales representatives can provide you with a pricing and availability quote for Toshiba PLCs that you are looking for in seconds.
If you do not have the part numbers for Toshiba Programmable Logic Controllers, our application engineers will be able to help
you figure out the part numbers and get the price quote to you as soon as possible.
|
|
|
 |
|
|
Can't find a part number?
E-mail Us. |
IDEC PLC
A Dedicated PID Control Module
is available for extreme stability and complex applications. This particular module has more functionality than any other
controller on the market. Independent of CPU scan time, the PID Control module does the work, reducing PLC scan time without
taking up PLC memory space. The new embedded Ethernet MicroSmart Pentra with web server functions boasts powerful
features
|
Panasonic PLC
FP2SH is a compact PLC series W140 x H100 x
D110 mm W5.51 x H3.94 x D4.33 in (when using 5-module type) loaded with multiple functions, achieving superior cost performance.
The CPU units have an RS232C port as standard equipment, which allows for communications with external equipment, such as a
computer or a display panel, and advanced communications for remote monitoring and remote maintenance via a modem.
|
|
|