VMX Series Compact
The VMX Series is a digitally programmable solid-state reduced voltage soft starter. Its six SCR design
features a voltage/current ramp with an anti-oscillation circuit for smooth load acceleration. The SCRs are sized to withstand
starting currents of 350% for 30 seconds and up to 600% for 10 seconds. The VMX Series features smooth, stepless ramp control,
which reduces motor inrush current and excessive wear on the mechanical drive train components. The VMX Series includes a
programmable keypad for setting operating parameters for the ideal starting cycle and protection features, plus easy to
understand diagnostic LEDs.
|
|
 VMX Series |
|
VMX-S Series Standard Duty "Configured"
VMX-S series soft starters are designed for lighter duty loads (like many pumps, fans and blowers) where a
soft starter rated at 350% for 30 seconds is more than adequate. Same great performance features and accessories you would find
in the "Heavy Duty" offering, only supplied with a shunt duty rated integral bypass contactor instead of a line rated contactor.
A cost-effective and reliable motor starting solution for standard duty applications.
- Standard VMX Series features
- 500% rated for 30 seconds
- Prepackaged combination or non-combo starters
- Built-in circuit breaker or fusible disconnect option with door-mounted lockable operator handle
- NEMA 4/12 enclosure
- Integral line-start (ATL) rated bypass contactor
- Advanced motor protection
- Control power transformer
- Interface board for easy control connections
- Door mounted keypad & pilot devices
|
|
 VMX-S Series |
|
Starting torque, ramp time, current limit, dual ramp, and Decel control are standard features on the VMX
Series, as well as the integrated Batch Process Timer and Time Clock Controller used for automated applications. By simply
adjusting the unit's starting torque, ramp time and current limit functions, the starting electrical characteristics of the motor
can be matched to the mechanical characteristics of the drive train for controlled acceleration of the load. The VMX Series
includes solid-state electronic overload protection in addition to numerous other protective features. It requires 120VAC (220VAC
optional) control power and uses dry contact inputs for Start / Stop control. Programmable auxiliary contacts and provisions for
interlocking are also included.
The Motortronics VMX Series starters are current rated controllers. Max. Amp ratings are for continuous duty
and must not be exceeded. Always check the motor nameplate FLA and Service Factor to ensure proper sizing. Each size has an
adjustable current range from 50% to 100% of the Max Amp rating.
VMX Series Soft Starter with Integral Bypass Contactor - NEMA & IEC Ratings
Model Number |
AMPS |
Max FLA |
Nominal Motor Rating (50/60 Hz) |
Nominal Motor Rating (50 Hz) |
| Maximum HP/Voltage (NEMA) |
Maximum kW/Voltage (IEC) |
| 200 V/HP |
230 V/HP |
460 V/HP |
575 V/HP |
220 V/kW |
380 V/kW |
415 V/kW |
| HD |
SD |
HD |
SD |
HD |
SD |
HD |
SD |
HD |
SD |
HD |
SD |
HD |
SD |
HD |
SD |
| VMX-18-BP |
9-18 |
11 |
18 |
3 |
5 |
3 |
5 |
7.5 |
10 |
7.5 |
15 |
2.2 |
3.7 |
3.7 |
7.5 |
5.5 |
7.5 |
| VMX-28-BP |
14-28 |
21 |
28 |
5 |
7.5 |
5 |
7.5 |
15 |
20 |
15 |
25 |
5.5 |
7.5 |
7.5 |
11 |
7.5 |
11 |
| VMX-39-BP |
19-39 |
27 |
39 |
7.5 |
10 |
7.5 |
10 |
20 |
25 |
20 |
30 |
7.5 |
11 |
11 |
18.5 |
11 |
18.5 |
| VMX-48-BP |
24-48 |
40 |
48 |
10 |
10 |
10 |
15 |
25 |
30 |
25 |
40 |
11 |
11 |
18.5 |
22 |
18.5 |
22 |
| VMX-62-BP |
31-62 |
45 |
62 |
10 |
15 |
15 |
20 |
30 |
40 |
30 |
60 |
11 |
15 |
22 |
30 |
22 |
30 |
| VMX-78-BP |
39-78 |
55 |
78 |
15 |
20 |
20 |
25 |
40 |
50 |
40 |
75 |
15 |
18.5 |
22 |
37 |
30 |
37 |
| VMX-92-BP |
46-92 |
68 |
92 |
20 |
25 |
25 |
30 |
50 |
60 |
50 |
75 |
18.5 |
22 |
30 |
45 |
37 |
45 |
| VMX-112-BP |
56-112 |
80 |
112 |
25 |
30 |
30 |
40 |
50 |
75 |
50 |
100 |
22 |
30 |
37 |
55 |
45 |
55 |
| VMX-150-BP |
75-150 |
96 |
150 |
30 |
40 |
30 |
50 |
60 |
100 |
60 |
125 |
22 |
45 |
45 |
75 |
55 |
75 |
| VMX-160-BP |
80-160 |
125 |
160 |
40 |
50 |
40 |
60 |
75 |
125 |
75 |
150 |
30 |
45 |
55 |
75 |
55 |
75 |
| VMX-210-BP |
105-210 |
156 |
210 |
50 |
60 |
60 |
75 |
100 |
150 |
125 |
200 |
45 |
55 |
75 |
110 |
75 |
110 |
| VMX-275-BP |
138-275 |
220 |
275 |
60 |
75 |
75 |
100 |
150 |
200 |
150 |
250 |
55 |
75 |
110 |
132 |
110 |
150 |
| VMX-361-BP |
181-361 |
248 |
361 |
75 |
125 |
100 |
125 |
200 |
300 |
200 |
350 |
75 |
110 |
132 |
185 |
132 |
200 |
| VMX-450-BP |
225-450 |
400 |
450 |
125 |
150 |
125 |
150 |
250 |
350 |
300 |
450 |
110 |
132 |
200 |
220 |
220 |
250 |
| VMX-550-BP |
275-550 |
480 |
550 |
150 |
150 |
200 |
200 |
400 |
450 |
500 |
500 |
132 |
160 |
250 |
285 |
265 |
305 |
| VMX-600-BP |
300-600 |
600 |
600 |
200 |
200 |
250 |
250 |
500 |
500 |
600 |
600 |
185 |
185 |
300 |
315 |
330 |
330 |
| VMX-862-BP |
431-862 |
690 |
852 |
250 |
250 |
250 |
300 |
500 |
600 |
600 |
700 |
200 |
250 |
360 |
450 |
380 |
475 |
| VMX-900-BP |
450-900 |
800 |
900 |
250 |
300 |
300 |
350 |
600 |
700 |
600 |
900 |
220 |
275 |
420 |
470 |
440 |
500 |
| VMX-1006-BP |
503-1006 |
960 |
1006 |
300 |
350 |
350 |
400 |
700 |
800 |
900 |
1000 |
255 |
310 |
475 |
525 |
500 |
555 |
| VMX-1250-BP |
625-1250 |
1080 |
1250 |
350 |
450 |
450 |
450 |
900 |
1000 |
1000 |
1200 |
330 |
385 |
565 |
655 |
600 |
695 |
|
Bypass packages available in NEMA 1, 4 & 12
Data is based on NECTable 430-150, full load current three-phase motors. Size soft starter based on actual
motor nameplate FLA.
Heavy duty rating (HD): 500% capacity for 60 seconds, 1.15 S.F., Line start (A-T-L) full voltage bypass
(except VMX-1250-BP which is shunt rated only).
Standard duty rating (SD): 500% capacity for 20 seconds, 1.0 S.F., shunt rated bypass. Added "-N" to the model
number for NEMA 1 or "-E" for NEMA 12.
|
For NEMA 1 ventilated applications, or for OEM purposes where a bypass contactor will be added by others,
VMX-210 models and above can be selected without the integral Bypass by substituting the -BP suffix with a -P suffix.
Whether we have Motortronics VMX-H series in stock in or need to ship direct from Phasetronics to any USA
cities; CTi Automation can get heavy duty configured soft start to you fast and save you some money. Our industrial factory
automation supplies distributors warehouse stocks some Motortronics products enabling us to further assist you in finding the
correct soft starter with integral bypass contactor in the USA, Canada, or Mexico. It will be very helpful if you have the
digital solid state soft start part numbers ready, then our sales representatives can provide you with a pricing and availability
quote for Motortronics VMX-C series that you are looking for in seconds. If you do not have the part numbers for Phasetronics
low voltage starters, our application engineers will be able to help you figure out the part numbers and get the price