100 Series Kulka 670A GP Series 3/8" Center Lines, Closed Back 150 Volt, 20 Amp
- Base, General Purpose Phenolic, 150°C
- Closed Back Design
- Screws, #6-32 Binder Head, Phil-Slot, Steel
- Terminals, Plated Brass
- 1-36 Poles
- 3/8" Centers
- Wire Range With Wire Binding Screw #12-#22 AWG - 20 Amps
- Wire Range With Sems Pressure Screw #18-#22 AWG Stranded Copper Wire Only, 150 Volts 15 Amps
- The Suitability Of These Devices For Greater Currents Shall Be Determined In The End-Use Application
- UL Recognized File No. XCFR2.E62806
- CSA Certified File No. LR19766
- CE Mark
|
 Marathon 100 Series Double Row Terminals |
|
If you are looking for Marathon Double Row Terminal Blocks, please call us at (800) 894-0412 or
email us at info@ctiautomation.net
we will do our best to help you find the Marathon Double Row Terminals that you are looking for at the most competitive prices possible. If
you are searching for Marathon Kulka Series Double Row Terminal Block technical information (data-sheets) please use the
Marathon Double Row Terminal Datasheets OR
Product Selection Guide page links.
|
200 Series Kulka 671 GP Series 7/16" Center Lines, Closed Back 300 Volt, 20 Amp
- Base, General Purpose Phenolic, 150°C
- Closed Back Design
- Screws, #6-32 Binder Head, Phil-Slot, Steel
- Terminals, Plated Brass
- 1-30 Poles
- 7/16" Centers
- Wire Range With Wire Binding Screw #12-#22 AWG - 20 Amps
- Wire Range With Sems Pressure Screw #12-#22 AWG Stranded Copper Wire Only, 20 Amps
- Will Accommodate Lugs For Wire Sizes #10-#16 AWG - 30 Amps
- The Suitability Of These Devices For Greater Currents Shall Be Determined In The End-Use Application
- UL Recognized File No. XCFR2.E62806
- CSA Certified File No. LR19766
- CE Mark
|
 Marathon 200 Series Double Row Terminals |
200 HB Series (High Barrier) 7/16" Center Lines, Closed Back 600 Volt, 20 Amp
- Base, General Purpose Phenolic, 150° C
- Closed Back Design
- Screws, #6-32 Binder Head, Phil-Slot, Steel
- Terminals, Plated Brass
- 1-30 Poles
- 7/16" Centers
- Wire Range With Wire Binding Screw #12-#22 AWG - 20 Amps
- Wire Range With Sems Pressure Screw #12-#22 AWG Stranded Copper Wire Only, 20 Amps
- Will Accommodate Lugs For Wire Sizes #10-#16 AWG - 30 Amps
- The Suitability Of These Devices For Greater Currents Shall Be Determined In The End-Use Application
- UL Recognized File No. XCFR2.E62806
- CSA Certified File No. LR19766
- CE Mark
|
 Marathon 200 HB Series High Barrier Double Row Terminals |
300 Series Kulka 672 GP Series 9/16" Center Lines, Closed Back 600 Volt, 30 Amp
- Base, General Purpose Phenolic, 150°C
- Closed Back Design
- Screws, #8-32 Binder Head, Phil-Slot, Steel
- Terminals, Plated Brass
- 1-24 Poles
- 9/16" Centers
- Wire Range with Wire Binding Screw # 10 - #14 AWG - 30 Amps
- Wire Range with Sems Pressure Screw #10 - #22 AWG Stranded Copper Wire Only, 30 Amps
- Will Accommodate Lugs for Wire Sizes #10 - #16 AWG - 30 Amps
- The Suitability of These Devices for Greater Currents Shall Be Determined in the End-Use Application
- UL Recognized File No. XCFR2.E62806
- CSA Certified File No. LR19766
- CE Mark
|
 Marathon 300 Series Double Row Terminals |
400 Series 11/16" Center Lines, Closed Back 600 Volt, 30 Amp
- Base, General Purpose Phenolic, 150°C
- Closed Back Design
- Screws, #10-32 Binder Head, Phil-Slot, Steel
- Terminals, Plated Brass
- 1-12 Poles
- 11/16" Centers
- Wire Range With Wire Binding Screw #10-#22 AWG - 30 Amps
- Wire Range With Sems Pressure Screw #10-#22 AWG Stranded Copper Wire Only, 30 Amps
- Will Accommodate Lugs For Wire Sizes #6-#16 AWG - 65 Amps
- The Suitability Of These Devices For Greater Currents Shall Be Determined In The End-Use Application
- UL Recognized File No. XCFR2.E62806
- CSA Certified File No. LR19766
- CE Mark
|
 Marathon 400 Series Double Row Terminals |
Kulka 410 GP Series 1/4" Center Lines, Open Back 300 Volt, 5 Amp
- Base, Phenolic, 150°C
- Open Back Design (Insulator Strip Required for Voltage Rating)
- JJ (GDI-30F) Material Available
- Screws, #2-56 X 7/32 Binder Head, Phil-Slot, Brass
- Terminals, Plated Brass
- 1-23 Poles
- 1/4" Centers
- Wire Range With Wire Binding Screw #18-#20 AWG - 5 Amps
- The Suitability Of These Devices For Greater Currents Shall Be Determined In The End-Use Application
- UL Recognized File No. XCFR2.E47811
- CSA Certified File No. LR19766
- CE Mark
|
 Marathon 410GP Series Double Row Terminals |
Kulka 600 GP Series 3/8" Center Lines, Open Back 300 Volt, 15 Amp
- Base, Phenolic, 150°C
- JJ (GDI-30F) Material Available
- Open Back Design (Insulator Strip Required for Voltage Rating)
- Screws, #5-40 Binder Head, Phil-Slot, Brass
- Terminals, Plated Brass
- 1-22 Poles
- The Suitability Of These Devices For Greater Currents Shall Be Determined In The End-Use Application
- 3/8" Centers
- Wire Range With Wire Binding Screw #12-#22 AWG - 15 Amps
- UL Recognized File No. XCFR2.E47811
- CSA Certified File No. LR19766
- CE Mark
|
 Marathon 600GP Series Double Row Terminals |
Kulka 600A/800A GP Series 3/8" Center Lines, Open Back 300 Volt, 15 Amp
- Base, Phenolic, 150°C
- JJ (GDI-30F) Material Available
- Open Back Design (Insulator Strip Required for Voltage Rating)
- Screws, #6-32 Binder Head, Phil-Slot, Steel
- Terminals, Plated Brass
- 1-22 Poles
- The Suitability Of These Devices For Greater Currents Shall Be Determined In The End-Use Application
- 3/8" Centers
- Wire Range With Wire Binding Screw #12-#22 AWG - 15 Amps
- 800A Series (Riveted KTs)
- UL Recognized File No. XCFR2.E47811
- CSA Certified File No. LR19766
- CE Mark
|
 Marathon 600A/800A Double Row Terminals |
Kulka 601/801 GP Series 7/16" Center Lines, Open Back 300 Volt, 20 Amp
- Base, General Purpose Phenolic, 150°C
- JJ (GDI-30F) Material Available
- Open Back Design (Insulator Strip Required for Voltage Rating)
- Screws, #6-32 Binder Head, Phil-Slot, Steel
- Terminals, Plated Brass
- 1-23 Poles
- 7/16" Centers
- Wire Range With Wire Binding Screw #12-#22 AWG - 20 Amps
- Will Accommodate Lugs For Wire Sizes #10-#16 AWG - 30 Amps
- The Suitability Of These Devices For Greater Currents Shall Be Determined In The End-Use Application
- 801 Series (Riveted KTs)
- UL Recognized File No. XCFR2.E47811
- CSA Certified File No. LR19766
- CE Mark
|
 Marathon 601/801 Double Row Terminals |
Kulka 602/802 GP Series 9/16" Center Lines, Open Back 300 Volt, 30 Amp
- Base, General Purpose Phenolic, 150°C
- JJ (GDI-30F) Material Available
- Open Back Design (Insulator Strip Required for Voltage Rating)
- Screws, #8-32 Binder Head, Phil-Slot, Steel
- Terminals, Plated Brass
- 1-26 Poles
- 9/16" Centers
- Wire Range With Wire Binding Screw #12-#14 AWG - 30 Amps
- The Suitability Of These Devices For Greater Currents Shall Be Determined In The End-Use Application
- 802 Series (Riveted KTs)
- UL Recognized File No. XCFR2.E47811
- CSA Certified File No. LR19766
- CE Mark
|
 Marathon 602/802 Double Row Terminals |
Kulka 603 GP Series 11/16" Center Lines, Open Back 600 Volt, 50 Amp
- Base, General Purpose Phenolic, 150°C
- JJ (GDI-30F) Material Available
- Open Back Design (Insulator Strip Required for Voltage Rating)
- Screws, #10-32 Binder Head, Phil-Slot, Steel
- Terminals, Plated Brass
- 1-12 Poles
- 11/16" Centers
- Wire Range With Wire Binding Screw #10-#12 AWG - 50 Amps
- Will Accommodate Lugs For Wire Sizes #6-#16 AWG - 65 Amps
- The Suitability Of These Devices For Greater Currents Shall Be Determined In The End-Use Application
- UL Recognized File No. XCFR2.E47811
- CSA Certified File No. LR19766
- CE Mark
|
 Marathon 603 GP Double Row Terminals |
Kulka 604 GP Series 7/8" Center Lines, Open Back 600 Volt, 70 Amp
- Base, General Purpose Phenolic, 150°C
- JJ (GDI-30F) Material Available
- Open Back Design (Insulator Strip Required for Voltage Rating)
- Screws, #12-32 Binder Head, Phil-Slot, Brass
- Terminals, Plated Brass
- 1-8 Poles
- 7/8" Centers
- Wire Range With Wire Binding Screw #4-#12 AWG - 70 Amps
- The Suitability Of These Devices For Greater Currents Shall Be Determined In The End-Use Application
- UL Recognized File No. XCFR2.E47811
- CSA Certified File No. LR19766
- CE Mark
|
 Marathon 604 GP Double Row Terminals |
Kulka 605 GP Series 1 1/8" Center Lines, Open Back 600 Volt, 90 Amp
- Base, General Purpose Phenolic, 150°C
- JJ (GDI-30F) Material Available
- Open Back Design (Insulator Strip Required for Voltage Rating)
- Screws, #1/4-28 Binder Head, Slotted, Brass
- Terminals, Plated Brass
- 1-6 Poles
- 1-1/8" Centers
- Wire Range With Wire Binding Screw #2-#12 AWG - 90 Amps
- The Suitability Of These Devices For Greater Currents Shall Be Determined In The End-Use Application
- UL Recognized File No. XCFR2.E47811
- CSA Certified File No. LR19766
- CE Mark
|
 Marathon 605 GP Double Row Terminals |
Kulka 621 RZ Series 7/16" Center Lines, Closed Back 600 Volt, 20 Amp
- Base, Thermoplastic, 125°C (U.L. RTI)
- Closed Back Design
- Screws, #6-32 Binder Head, Phil-Slot, Steel
- Terminals, Plated Brass
- 1-30 Poles
- 7/16" Centers
- The Suitability Of These Devices For Greater Currents Shall Be Determined In The End-Use Application
- Wire Range With Wire Binding Screw #12-#22 AWG - 20 Amps
- Wire Range With Sems Pressure Screw #12-#22 AWG Stranded Copper Wire Only - 20 Amps
- UL Recognized File No. XCFR2.E62806
- CSA Certified File No. LR19766
- CE Mark
|
 Marathon 621 RZ Double Row Terminals |
Kulka 670A RZ Series 3/8" Center Lines, Closed Back 300 Volt, 20 Amp
- Base, Thermoplastic, 130°C (U.L. RTI)
- Closed Back Design
- Screws, #6-32 Binder Head, Phil-Slot, Steel
- Terminals, Plated Brass
- 1-30 Poles
- 3/8" Centers
- The Suitability Of These Devices For Greater Currents Shall Be Determined In The End-Use Application
- Wire Range With Wire Binding Screw #12-#22 AWG - 20 Amps
- Wire Range With Sems Pressure Screw #14-#22 AWG Stranded Or Solid Wire (Cat. Designation 3865)
- UL Recognized File No. XCFR2.E47811
- CSA Certified File No. LR19766
- CE Mark
|
 Marathon 670A RZ Double Row Terminals |
Kulka 671 RZ Series 7/16" Center Lines, Closed Back 300 Volt, 20 Amp
- Base, Thermoplastic, 125°C (U.L. RTI)
- Closed Back Design
- Screws, #6-32 Binder Head, Phil-Slot, Steel
- Terminals, Plated Brass
- 1-30 Poles
- 7/16" Centers
- The Suitability Of These Devices For Greater Currents Shall Be Determined In The End-Use Application
- Wire Range With Wire Binding Screw #12-#22 AWG - 20 Amps
- Wire Range With Sems Pressure Screw #12-#22 AWG Stranded Copper Wire Only - 20 Amps
- Will Accommodate Lugs For Wire Sizes #10-#16 AWG - 30 Amps
- UL Recognized File No. XCFR2.E62806
- CSA Certified File No. LR19766
- CE Mark
|
 Marathon 671 RZ Double Row Terminals |
Kulka 672 RZ Series 9/16" Center Lines, Closed Back 600 Volt, 30 Amp
- Base, Thermoplastic, 125°C (U.L. RTI)
- Closed Back Design
- Screws, #8-32 Binder Head, Phil-Slot, Steel
- Terminals, Plated Brass
- 1-24 Poles
- 9/16" Centers
- Wire Range With Wire Binding Screw #10-#14 AWG - 30 Amps
- Wire Range With Sems Pressure Screw #10-#22 AWG Stranded Copper Wire Only - 30 Amps
- The Suitability Of These Devices For Greater Currents Shall Be Determined In The End-Use Application
- UL Recognized File No. XCFR2.E47811
- CSA Certified File No. LR19766
- CE Mark
|
 Marathon 672 RZ Double Row Terminals |
|
Our Marathon Special Products distributors warehouse in Boise, Idaho USA stocks some Marathon products
enabling us to further assist you in finding the correct Marathon Double Row Terminals in the USA, Canada and Mexico. Whether we
have Marathon Double Row Terminal Blocks in stock in or need to ship direct from Marathon to any USA cities; CTi Automation can
get Marathon Terminal Blocks to you fast and save you some money!
It will be very helpful if you have the Marathon Terminals part numbers ready, then our sales
representatives can provide you with a pricing and availability quote for Marathon Double Row Terminals that you are
looking for in seconds. If you do not have the part numbers for Marathon Double Row Terminal Blocks, our application engineers
will be able to help you figure out the part numbers and get the price quote to you as soon as possible. |
|
|
 |
|
|
Can't find a part number?
E-mail Us! |
AC Tech Drives
The Input Voltage must match the nameplate
voltage rating of the drive. Voltage fluctuation must not vary by greater than 10% overvoltage or 15% undervoltage. The SCD drive
is suitable for use on a circuit capable of delivering not more than 5,000 RMS symmetrical amperes at 5 HP (3.7 kW) and below,
and 18,000 RMS symmetrical amperes at 7.5 - 25 HP (5.5 - 18.5 kW), at the drive's rated voltage.
|
Weidmuller Terminals
The P-Series
is Weidmüller's new generation of modular terminals distinguished by concise yet uniquely flexible portfolio. The cornerstones of
this concept is the "Push In" connection technology which enable a reduction in the terminal variants whilst providing incredible
cost savings. Save space by connecting with these multi-tier terminals with PUSH IN connection technology.
|
|
|