Principal Components of a 3-Phase Capacitor
The principal components of a 3-phase ABB capacitor include:
Sequential Protection System:
Self-Healing Capacitor Elements
One or more self-healing capacitor elements are installed for each phase. These elements are connected in Y or ?.
In case of dielectric breakdown, the fault is cleared by evaporation of the metalized layer around the breakdown
with negligible loss of capacitance and continued operation of the capacitor!
Internally Protected Elements
A unique Sequential Protection System including the IPE design (IPE - internally protected elements) ensures that
each individual element can be disconnected from the circuit at the end of the element's life.
Nonflammable Dry Vermiculite Filler
Vermiculite is a dry, granular insulating material that is solid, inert and fire proof. This material fills all
open spaces in the Enclosure to isolate the capacitor elements and exclude free oxygen.
Discharge Resistors
Discharge resistors (one for each phase) are sized to ensure safe discharge of the capacitor to less than 50 volts in one
minute or less as required by the NEC.
Terminal Studs
Large terminal studs are located inside the enclosure at the top of the capacitor for quick and easy cable connections.
Enclosure
All ABB enclosures are made of welded heavy gauge steel. Available enclosure types include Indoor NEMA 1, Outdoor Raintight,
and Indoor Dusttight. (RAL 7032, Beige)
What is a Metallized-Film Element?
Metallized-film is a microscopically thin layer of conducting material (called an electrode), usually aluminum or zinc on an
underlying layer of insulating film. The electrode thickness averages only .01 microns while insulating (polypropylene) film
ranges from 5 to 10 microns in thickness depending upon the design voltage of the capacitor (the higher the voltage rating,
the thicker the insulating film).
Advantages of Metallized-Film Elements
There are two electrode layers separated by one layer of insulating film. Thousands of these layers are tightly wound around a
core in such a manner that the edge of one electrode is exposed on one side of the element and the edge of the other electrode
is exposed on the other side of the element. See Fig. 1 & 2.
|
 |
Wires are then connected to each side of the element. The element is enclosed in a container and then
filled with a hardening protective sealant.
Self-Healing Design
Self-healing refers to a process where a short circuit between electrodes vaporizes the electrode around the fault until
the fault is eliminated. The element continues to function with negligible loss of performance.
Low Internal Losses
Due to the high dielectric efficiency of the metallized-film, the internal losses are extremely low. ABB metallized-film
design losses are limited to .5 watts per kvar including the losses across the discharge resistors.
Small Element Size
Due to the thin electrode and dielectric, metallized-film elements are small and compact in size resulting in smaller, more
powerful capacitors.
The capacitance of any element design is inversely proportional to the separation between electrodes. In other
words, if the separation between conducting surfaces is cut in half, the effective capacitance is doubled in addition to reducing
the physical size of the element by half.
More About Self Healing Elements
"Self-healing" is a characteristic which is unique to metallized electrode capacitors. All capacitors normally experience
insulation breakdown as a result of the accumulated effect of temperature, voltage stress, impurities in the insulating medium,
etc. When this happens in a non-"metallized" design, the electrodes are short-circuited and the capacitor ceases its production of
reactive power. In an ABB metallized-film unit, however, these individual insulation breakdowns do not mean the shutdown of the
capacitor. The faults self-heal themselves and the capacitor continues operation.
|
 Fig. 3. Two electrodes short circuit through a fault
in a dielectric layer. |
|
The conducting electrode is very thin; when a short circuit develops as a result of a fault in the insulating
dielectric, the thin electrode vaporizes around the area of the fault. This vaporization continues until sufficient separation
exists between the faulted electrodes to overcome the voltage level.
|
 Fig. 4 illustrates "self-healing". The electrode
layers in the area where they were short circuiting have been vaporized, thereby eliminating the short circuit. |
The entire process of self-healing takes "microseconds" and the amount of electrode which is lost is
negligible in comparison to the total surface area of the element. The result is the metallized-film unit may self-heal hundreds
of times during its long life and still retain virtually all of its rated capacitance.
The IPE Sequential Protection System
ABB's metallized-film self healing capacitor elements will have a longer life than their conventional foil design counterparts for the
above reason. However, accumulated effects of time, temperature, voltage stress, etc., eventually effect capacitor life.
ABB's sequential protection system featuring patented Internally Protected Elements (IPE) design provides
increased protection to facilities and personnel not available from other capacitor designs. This proven design allows for
self-healing throughout the life of the capacitor to insure the maximum length of reliable service and still provide short circuit
protection in each element when self-healing can no longer continue. This is accomplished by a combination of unique winding
construction and an internal fuse link (See Fig. 5) within each element which safely and selectively disconnects each individual
element. ABB Capacitors do not rely on mechanical pressure interrupters
and additional line fuses have disadvantages associated with that kind of construction. |
 Fig. 5 |
|
What are Discharge Resistors?
As all the capacitor elements store electrical power like a battery, the capacitor will maintain a near full charge even when not
energized. As this is a potentially dangerous condition to unsuspecting plant personnel that might be inspecting the capacitor terminals
and wiring, discharge resistors are connected between all of the terminals. When the capacitor is shut off, these discharge resistors
drain the capacitor elements of their stored electrical charge. It is recommended, however, that capacitor terminals should ALWAYS be
short-circuited before touching the Terminals.
What is the Significance of Dry Type Design?
ABB Low Voltage capacitors contain no free liquids and are filled with a unique nonflammable granular material called vermiculite.
Environmental and personnel concerns associated with leakage or flammability of conventional oil-filled units are eliminated; and kvar
for kvar, vermiculite filled units weigh 30% to 60% less than their oil filled counterparts.
Vermiculite is routinely used in the United States as an insulating material in the walls and ceilings of new buildings.
Its properties have been extensively documented and recognized as an ideal material for safety and environmental considerations.
|
|
|
 |
|
|