The MCH Series is a variable torque AC Tech Drive for HVAC applications and is available with options such as bypass, line reactor, and input disconnect or circuit breaker. The MCH Series AC Tech drives also include PID setpoint control as a standard feature. Designed for HVAC Professionals, the AC Tech MCH Series is an ideal solution for flow and volume control of fans, pumps and cooling towers. Variable frequency drives not only provide better regulation of the system (and thereby greater comfort), but save significant energy compared with traditional damper or valve systems.

These NEMA 1 controls are available from 1/4 hp to 250 hp. "Contractor Ready" assemblies feature a hinged cover and installed options that can include a disconnect & fuses, line reactor and/or 3-contactor bypass. AC Tech has been serving the HVAC project market for over 15 years with tens of thousands of installations world-wide.

AC Tech MCH Series HVAC Drives Distributors
MCH Series

If you are looking for AC Tech HVAC Drives, please call us at (800) 894-0412 or email us at info@ctiautomation.net we will do our best to help you find the AC Tech Drives that you are looking for at the most competitive prices possible. If you are searching for AC Tech MCH series HVAC drive technical information (data-sheets) please use the datasheets or product selection guide page links.

The MCH Series AC Tech Drive is designed to operate Standard Polyphase Induction Motors rated for 200, 230, 400, 460 or 575VAC from 0 to 120Hz. The MCH Series AC Tech Drive offers intuitive operator interface using plain english programming and operational information. Let the drive software adjust the motor speed to maintain a preset pressure, flow, temperature or other independent variables using PID Setpoint Control. The MCH Series AC Tech HVAC Drives include UL and cUL approved motor protection device for single motor applications. The MCH Series AC Tech Variable Frequency Drive has been specifically designed for HVAC loads such as fans, pumps and cooling towers. The application specific keypad offers easy operation. Features especially useful for fan or pump applications include:

  • HOA keys to mimic traditional Hand, Off, and Auto functions
  • PID set point control
  • Hour and kWh meters
  • 32 character plain English backlit LCD display with adjustable viewing angle

MCH Series AC Tech Drives installed options include, Branch Circuit Protection: Choose either a Circuit Breaker or Disconnect with fusing, both offer door interlocked rotary handle. If branch circuit protection is located elsewhere, door interlocked disconnect switch is available without fusing. Input Line Reactor: The most recommended complement to a good drive installation. The input reactor adds protection for the drive against common electrical noise and line spikes while reducing noise and harmonics back to the supply mains. Drive Bypass: Three-contactor drive bypass completely isolates the drive when operating the motor at full speed directly across the line. Contactor logic and controls are operated at 115VAC and include pilot light operators & door mounted controls. The MCH Series AC Tech VFD is available with an Option Box that allows options such as input disconnect switch, input fuses, and/or input line reactor to be added to the drive. These options are factory assembled and wired in a NEMA 1 enclosure. AC Tech MCH Series VFD offers the best flow control solution based on factors like energy savings and fast payback.

What is the Bypass and how does it work?
The Bypass option allows the motor to be operated across line power in the event that the drive is unavailable, or if continued operation at full speed is required. The AC Tech bypass consists of three contactors. In Drive mode, the VFD input and output contactors are closed, and the Bypass contactor is open. In Bypass mode, the VFD input and output contactors open to fully isolate the drive, while the Bypass contactor closes to apply line power directly to the motor. Control logic is provided to insure proper sequencing of the contactors. The AC Tech Bypass also has a Drive Test mode, which closes the VFD input contactor (the output contactor remains open), allowing the drive to be configured and programmed while the motor is running in Bypass.

Why are three contactors better than two?
Some drive suppliers only use two contactors in their bypass for a cheaper design. They do not utilize a VFD input contactor, which means that even in Bypass mode, power is still applied to the drive. If a short circuit were to occur in the drive portion of the unit, attempting to apply main power would result in clearing input fuses or tripping the input breaker. This renders the bypass useless, which means the motor cannot be operated (thus defeating the purpose of the bypass). By having the third contactor to completely isolate the drive, the AC Tech bypass will still operate, insuring critical equipment remains on line.

MH200 Series AC Tech HVAC Drives are rated for 240/200 Vac, 50-60 Hz input. The drive will function with input voltages of 200 to 240 Vac (+ 10%, - 15%), at 48 to 62 Hz. MH400 Series AC Tech Inverters are rated for 480/400 Vac, 50-60 Hz input. The drive will function with input voltages of 400 to 480 Vac (+ 10%, - 15%), at 48 to 62 Hz. MH500 Series AC Tech VFD Drives are rated for 590/480 Vac, 50-60 Hz input. The drive will function with input voltages of 480 to 590 Vac (+ 10%, - 15%), at 48 to 62 Hz.

Model Number Power Current Output Dimensions inches (mm)
Hp kW H W D
NEMA 1 Models - 208/240 Volt 3 Phase input
MH210B 1 0.75 4.0 7.50 (190) 4.70 (119) 4.33 (110)
MH220B 2 1.5 6.8 7.50 (190) 6.12 (155) 5.12 (130)
MH230B 3 2.2 9.6 7.50 (190) 6.12 (155) 5.12 (130)
MH250B 5 4.0 15.2 7.88 (200) 7.86 (200) 5.94 (151)
MH275B 7.5 5.5 22 9.38 (238) 7.86 (200) 6.84 (174)
MH2100B 10 7.5 28 11.25 (286) 7.86 (200) 6.84 (174)
MH2150B 15 11 42 12.75 (324) 7.86 (200) 6.84 (174)
MH2200B 20 15 54 12.75 (324) 10.26 (261) 7.74 (197)
MH2250B 25 18.5 68 15.75 (400) 10.26 (261) 8.35 (212)
MH2300B 30 22 80 15.75 (400) 10.26 (261) 8.35 (212)
MH2400B 40 30 104 25.00 (635) 13.00 (330) 10.50 (267)
MH2500B 50 37.5 130 25.00 (635) 13.00 (330) 10.50 (267)
MH2600B 60 45 154 47.00 (1194) 16.64 (423) 11.85 (301)
Model Number Power Current Output Dimensions inches (mm)
Hp kW H W D
NEMA 4 Models - 208/240 Volt 3 Phase input
MH210C 1 0.75 4.0 7.88 (200) 6.12 (155) 4.35 (110)
MH220C 2 1.5 6.8 7.88 (200) 7.86 (200) 4.90 (124)
MH230C 3 2.2 9.6 7.88 (200) 7.86 (200) 5.90 (150)
MH250C 5 4.0 15.2 9.75 (248) 10.26 (261) 7.20 (183)
MH275C 7.5 5.5 22 11.75 (298) 10.26 (261) 8.35 (212)
MH2100C 10 7.5 28 13.75 (349) 10.26 (261) 8.35 (212)
MH2150C 15 11 42 15.75 (400) 10.26 (261) 8.35 (212)
Model Number Power Current Output Dimensions inches (mm)
Hp kW H W D
NEMA 12 - 208/240 Volt 3 Phase input
MH2200D 20 15 54 15.75 (400) 10.26 (261) 8.35 (212)
MH2250D 25 18.5 68 20.25 (514) 10.26 (261) 8.35 (212)
MH2300D 30 22 80 20.25 (514) 10.26 (261) 8.35 (212)
MH2400D 40 30 104 31.00 (787) 14.00 (356) 11.85 (301)
MH2600D 60 45 154 37.00 (940) 18.00 (457) 13.30 (338)
Model Number Power Current Output Dimensions inches (mm)
Hp kW H W D
NEMA 1 Models - 400/480 Volt 3 Phase input
MH410B 1 0.75 2.3 7.50 (190) 4.70 (119) 3.63 (92)
MH420B 2 1.5 3.9 7.50 (190) 6.12 (155) 4.22 (107)
MH430B 3 2.2 5.5 7.50 (190) 6.12 (155) 5.12 (130)
MH450B 5 4.0 8.7 7.50 (190) 6.12 (155) 5.12 (130)
MH475B 7.5 5.5 12.6 9.38 (238) 7.86 (200) 6.25 (159)
MH4100B 10 7.5 16.0 9.38 (238) 7.86 (200) 6.84 (174)
MH4150B 15 11 24 11.25 (286) 7.86 (200) 6.84 (174)
MH4200B 20 15 31 12.75 (324) 7.86 (200) 6.84 (174)
MH4250B 25 18.5 39 12.75 (324) 10.26 (261) 7.74 (197)
MH4300B 30 22 46 12.75 (324) 10.26 (261) 7.74 (197)
MH4400B 40 30 60 15.75 (400) 10.26 (261) 8.35 (212)
MH4500B 50 37.5 75 19.75 (502) 10.26 (261) 8.55 (217)
MH4600B 60 45 88 19.75 (502) 10.26 (261) 8.55 (217)
MH4750B 75 55 96 29.00 (737) 16.64 (423) 11.85 (301)
MH41000B 100 75 124 29.00 (737) 16.64 (423) 11.85 (301)
MH41250B 125 90 156 29.00 (737) 24.42 (620) 11.85 (301)
MH41500B 150 110 180 29.00 (737) 24.42 (620) 11.85 (301)
MH42000B 200 150 240 29.00 (737) 36.66 (931) 11.85 (301)
MH42500B 250 185 300 29.00 (737) 36.66 (931) 11.85 (301)
Model Number Power Current Output Dimensions inches (mm)
Hp kW H W D
NEMA 4 Models - 400/480 Volt 3 Phase input
MH410C 1 0.75 2.3 7.88 (200) 6.12 (155) 4.35 (110)
MH420C 2 1.5 3.9 7.88 (200) 7.86 (200) 4.90 (124)
MH430C 3 2.2 5.5 7.88 (200) 7.86 (200) 4.90 (124)
MH450C 5 4.0 8.7 7.88 (200) 7.86 (200) 5.90 (150)
MH475C 7.5 5.5 12.6 9.75 (248) 10.26 (261) 7.20 (183)
MH4100C 10 7.5 16.0 11.75 (298) 10.26 (261) 8.35 (212)
MH4150C 15 11 24 13.75 (349) 10.26 (261) 8.35 (212)
MH4200C 20 15 31 15.75 (400) 10.26 (261) 8.35 (212)
Model Number Power Current Output Dimensions inches (mm)
Hp kW H W D
NEMA 12 - 400/480 Volt 3 Phase input
MH4250D 25 18.5 39 15.75 (400) 10.26 (261) 8.35 (212)
MH4300D 30 22 46 15.75 (400) 10.26 (261) 8.35 (212)
MH4400D 40 30 60 20.25 (514) 10.26 (261) 8.35 (212)
MH4500D 50 37.5 75 21.00 (533) 13.72 (348) 8.35 (212)
MH4600D 60 45 88 21.00 (533) 13.72 (348) 8.35 (212)
MH4750D 75 55 96 37.00 (940) 18.00 (457) 13.30 (338)
MH41000D 100 75 124 39.00 (991) 26.00 (660) 13.30 (338)
MH41250D 125 90 156 39.00 (991) 26.00 (660) 13.30 (338)
Model Number Power Current Output Dimensions inches (mm)
Hp kW H W D
NEMA 1 Models - 575 Volt 3 Phase input
MH510B 1 0.75 1.6 7.50 (190) 4.70 (119) 3.63 (92)
MH520B 2 1.5 2.7 7.50 (190) 6.12 (155) 4.22 (107)
MH530B 3 2.2 3.9 7.50 (190) 6.12 (155) 5.12 (130)
MH551B 5 4.0 6.1 7.88 (200) 7.86 (200) 5.94 (151)
MH575B 7.5 5.5 9.0 9.38 (238) 7.86 (200) 6.25 (159)
MH5100B 10 7.5 11.0 9.38 (238) 7.86 (200) 7.40 (188)
MH5150B 15 11 17.0 12.75 (324) 7.86 (200) 6.84 (174)
MH5200B 20 15 22 12.75 (324) 7.86 (200) 7.40 (188)
MH5250B 25 18.5 27 12.75 (324) 10.26 (261) 7.74 (197)
MH5300B 30 22 32 12.75 (324) 10.26 (261) 8.25 (210)
MH5400B 40 30 41 15.75 (400) 10.26 (261) 8.35 (212)
MH5500B 50 37.5 52 19.75 (502) 10.26 (261) 8.55 (217)
MH5600B 60 45 62 19.75 (502) 10.26 (261) 8.55 (217)
Model Number Power Current Output Dimensions inches (mm)
Hp kW H W D
NEMA 4 Models - 575 Volt 3 Phase input
MH510C 1 0.75 1.6 7.88 (200) 6.12 (155) 4.35 (110)
MH520C 2 1.5 2.7 7.88 (200) 7.86 (200) 4.90 (124)
MH530C 3 2.2 3.9 7.88 (200) 7.86 (200) 4.90 (124)
MH550C 5 4.0 6.1 7.88 (200) 7.86 (200) 5.90 (150)
MH575C 7.5 5.5 9.0 9.75 (248) 10.26 (261) 7.20 (183)
MH5100C 10 7.5 11.0 11.75 (298) 10.26 (261) 8.35 (212)
MH5150C 15 11 17.0 13.75 (349) 10.26 (261) 8.35 (212)
MH5200C 20 15 22 15.75 (400) 10.26 (261) 8.35 (212)
Model Number Power Current Output Dimensions inches (mm)
Hp kW H W D
NEMA 12 Models - 575 Volt 3 Phase input
MH5250D 25 18.5 27 15.75 (400) 10.26 (261) 8.35 (212)
MH5300D 30 22 32 15.75 (400) 10.26 (261) 8.35 (212)
MH5400D 40 30 41 20.25 (514) 10.26 (261) 8.35 (212)
MH5500D 50 37.5 52 21.00 (533) 13.72 (348) 8.35 (212)
MH5600D 60 45 62 21.00 (533) 13.72 (348) 8.35 (212)

Whether we have AC Tech enclosed-micro drives in stock in Boise Idaho or need to ship direct from AC Tech to any USA cities; CTi Automation can get AC Tech drives to you fast and save you some money. Our industrial factory automation supplies distributors warehouse stocks some Lenze AC Tech products enabling us to further assist you in finding the correct AC Tech drives in the USA, Canada, or Mexico. It will be very helpful if you have the AC Tech enclosed-micro drive part numbers ready, then our sales representatives can provide you with a pricing and availability quote for AC Technology inverters that you are looking for in seconds. If you do not have the part numbers for AC Tech VFD drives, our application engineers will be able to help you figure out the part numbers and get the price quote to you as soon as possible.

Stock Check
Part No:
OR
Manufacturer:

Search Tips

Can't find a part number?
E-mail Us.

FUJI Drives

FUJI 3-Phase, 208V Class inverters of 5 HP or less (FRENIC-Eco series) were the products of which were restricted by the "Guideline for Suppressing Harmonics in Home Electric and General-purpose Appliances" issued by the Ministry of Economy, Trade and Industry. In addition to optimizing the control of the applied motor for Energy-Savings, FRENICEco series drives also

Motortronics

The ASD-NANOCOM Interface has been designed for quick and simple installation. The card is connected to the drive's control board via two 2x13-pin connectors. No additional mechanical support is required, and the only tool required for installation is a small flat screwdriver for wiring the network cable to the drive's RS-485 pluggable terminal block.